POWER TRANSFORMER
High-voltage oil-immersed equipment for utility, railway, mining, industrial and renewable-energy power systems.
PRODUCT OVERVIEW
The supplied 35kV record covers 1000–10000 kVA oil-immersed power transformers with ONAN and ONAF dual cooling. The compact layout, dependable insulation and flexible voltage regulation support long-term utility and infrastructure operation.
Capacity, secondary voltage, vector group, cooling, high-altitude adaptation and certification are confirmed per project. The Kazakhstan case documents eight 35kV transformers for railway infrastructure in a harsh climate.
CORE FEATURES
Low-loss construction reduces operating energy use and long-run ownership cost.
Natural or fan-assisted oil cooling adapts output to load variation.
High-grade insulation supports power-frequency, induced and impulse withstand requirements.
Tap-change options support stable output when grid voltage fluctuates.
Protection assemblies support rapid fault response and safe, stable operation.
Project engineering can address low temperature, wind-sand and anti-condensation requirements.
TECHNICAL PARAMETERS
The final data sheet is issued after the duty, standards and site conditions are confirmed.
| Parameter | Supplied range / option |
|---|---|
| Rated power | 1000, 2000, 3150, 4000, 5000, 6300, 8000 or 10000 kVA |
| Primary voltage | 35 kV ±2 × 2.5% or ±3 × 2.5% |
| Secondary voltage | 6.3, 10.5, 11 or 20 kV |
| Cooling | ONAN / ONAF dual cooling |
| Frequency | 50 Hz; 60 Hz available on request |
| Vector group | Dyn11 or YNd11; standard Dyn11 |
| Winding material | High-purity oxygen-free copper |
| Efficiency | ≥98.0%–99.7%, increasing with rated power |
| Standards | IEC 60076, GB/T 1094 and agreed project requirements |
APPLICATIONS
Use the 35kV route where project-specific engineering, high capacity and dependable service support are required.
PROJECT PROOF
FAQ
ONAN / ONAF selection follows the load profile, ambient conditions and required full-load output.
Yes. The supplied record lists several secondary voltages and Dyn11 or YNd11 vector groups for project review.
Routine and type-test records, ratio, resistance, no-load, load and withstand test documentation are prepared for the approved configuration.
The supplied record describes approximately 30–45 days after deposit and full technical confirmation, subject to quantity and configuration.